GenICam Working Group Updates

During the International Vision Standard Meeting in Prague in April which was hosted by the EMVA, the GenICam working group has released two module updates with the following details:
Module – Standard Features Naming Convention (SFNC) version 2.8:

1. New Features and Component Additions
  • Added CoordinateMapA and CoordinateMapB component types.
  • Added A and B coordinate map support for Scan 3D Projection output mode.
  • Added Scan 3D Projection output mode.
  • Added Scan3dCoordinateMapEnable for enhanced 3D scanning workflows.
  • Added JPEG XS support as a new compression/encoding option.
  • Added UserSetReset feature.
2. Units and Standards Improvements
  • Updated electrical units: Volt → V, Amp → A.
  • Added these updated units to the Standard Units table.
  • Added missing ns (nanoseconds) unit to the standards list.
  • Set ns as the unit for all timestamp related features for consistency.
3. Clarifications and Requirements
  • Added notes outlining requirements for Trigger, Exposure, and Gain features.
  • Clarified usage and units for EncoderResolution and DeviceLinkSpeed.
  • Clarified GroupSelector Interface type behavior when very large numbers of groups are present.
  • Made all Device SFNC version features mandatory to ensure consistent versioning.
4. GigE Vision and CoaXPress Updates
  • Added GevStreamingMode and GevControlChannelMaxPacketSize for improved GigE Vision configuration for the upcoming GigE Vision 3.0 specification.
  • Removed explicit CXP link speed reference and added clarifications around test mode behavior.
5. General Corrections
  • Miscellaneous minor corrections, text clarifications, and precision improvements throughout the document.

Module – GenDC version 1.2:

  • Introduced support for JPEG-XS payloads
  • Miscellaneous clarifications have been added to ensure better interoperability